Take a TourHere is a glimpse of HAWKE’s solutions for the different Markets. Try out some Hawke Solutions.
Take a Tour of the Markets We ServeA quick look through the various markets we are equipped to cater. See the Hawke markets.
Transcript
00:05The 501321 cable. Gland consists of three key components,
00:10entry and IP seal and the back nut.
00:13This exe cable Gland is designed for use with non armoured elastomer and plastic insulated
00:19cables. This cable Gland may be used with brady cables
00:23where the braid and outer sheath pass into the enclosure.
00:27The braid must be suitably terminated inside the enclosure assembly.
00:31Instructions are provided with Hawk cable lands or can be downloaded by the Hawk website allow
00:38sufficient length of cable to suit the equipment.
00:41The cable is being terminated into past the cable through the
00:47cable Gland. Please note if the equipment has a threaded
00:51entry, it may be advisable to screw the cable Gland into the equipment to prevent twisting of
00:57the cable. The method of installation may vary depending
01:01on the enclosure type, hold the entry position with a
01:09spanner or wrench to prevent rotation and tighten the back nut using a spanner or wrench
01:14until resistance is felt between the seal and the cable then turn the back nut through a
01:20further half to one full turn to complete the inner seal installation is complete