HUBBELL CANADA
High Bay Occupancy Sensor, 24V DC, Passive Infrared (PIR)
Image of HMHB2LV High Bay Occupancy Sensor, 24V DC, Passive Infrared (PIR)
Image of HMHB2LV High Bay Occupancy Sensor, 24V DC, Passive Infrared (PIR)
Discontinued

High Bay Occupancy Sensor, 24V DC, Passive Infrared (PIR)

Brand: Hubbell Wiring Device-Kellems

Catalog ID: HMHB2LV

Switches and Lighting Controls, Occupancy Sensors, High Bay, 24V DC, 1.4

  • Fixture or work box mounting with ½" threaded nipple
  • Supplied with 360º lens
  • aisle, end-of-aisle and 180º lenses available separately
  • Digital passive infrared (PIR) sensor

Standard Product

General

Application

Area and Aisle Coverage

Catalog Number

HMHB2LV

Control Output

Input Voltage

Environmental Conditions

Indoor Dry Unless Protected By Additional Means

EU RoHS Indicator

Indicator(s) Type

PIR= Red LED

Item Type

High Bay Lighting Controls

Load Capacity

Load Is A Function Of The Control Unit

Material - Mounting Hardware

Screw Mounting

Operating Cycles

6,000 Cycles Minimum

Operating Temperature

32 Deg F to 104 Deg F (0 Deg C to 40 Deg C)

Performance

  • Electrical - Motor load - ¼-HP motor load @ 120V AC, 1/6 HP @ 347V
  • Electrical - User Interface - 2 four-pin dip switches
  • Environment - Operating temperature - 32°F to 149°F (0°C to 65°C)
  • Environment - Relative humidity - 0% to 95%
  • Timer time-outs - Primary - 8-second test mode – 4, 8, 16 and 30 minute time-outs
  • Timer time-outs - Secondary - Can be disabled – 30, 60 and 90 minute time-outs

Specifications

  • Casing - High-impact injection-molded thermoplastic
  • Size - 4.4 inch x 3.6 inch x 2.0 inch
  • Weight - 7 oz.

UPC

783585158723

Electrical Ratings

Sensitivity

Adjustable W

Supply Voltage

24V DC V

Certifications And Compliance

Environmental Conditions

Indoor Dry Unless Protected By Additional Means

EU RoHS Indicator

Industry Standard(s)

cULus Listed

Force Related

Load Capacity

Load Is A Function Of The Control Unit

Operational

Control Output

Input Voltage

Indicator(s) Type

PIR= Red LED

Operating Cycles

6,000 Cycles Minimum

Operating Temperature

32 Deg F to 104 Deg F (0 Deg C to 40 Deg C)

Performance

  • Electrical - Motor load - ¼-HP motor load @ 120V AC, 1/6 HP @ 347V
  • Electrical - User Interface - 2 four-pin dip switches
  • Environment - Operating temperature - 32°F to 149°F (0°C to 65°C)
  • Environment - Relative humidity - 0% to 95%
  • Timer time-outs - Primary - 8-second test mode – 4, 8, 16 and 30 minute time-outs
  • Timer time-outs - Secondary - Can be disabled – 30, 60 and 90 minute time-outs

Sensing Range

Up to 40' Mounting Height