Brand: Electro Composites
Catalog ID: 082-034-H-573-00
Electro Composites SDC™ composite bushings are designed to provide the toughest, cleanest and safest bushing solution for all HV applications. We make standard OEM and aftermarket form-fit-function replacement bushings for substation transformers, GSU transformers, oil circuit breakers, switchgear, wall/floor (air-air and oil-oil), HVDC and other applications. Available from 1kV up to 170kV with current ratings up to 21,500A. SDC™ (Solid Dielectric Capacitor) bushings have a one-piece cycloaliphatic epoxycore and integral sheds. All SDC bushings are solid dielectric insulation – oil–free construction, capacitance graded condenser core with internal CT pocket/ground shield and a flange test tap, available in bottom connected or draw-lead configurations. Made in accordance with the most current bushing standards: IEEE C57.19.01, CSA C88.1, IEC 60137.
Application
Generator
Bottom Terminal Type
CONTACT DISC 6.00 DIA WITH 4X 5/8-11 THREADED HOLES
Catalog Number
082-034-H-573-00
Color
Gray
Flange Type
2 Pieces
Immersion Type - Above Flange
Air
Immersion Type - Below Flange
Hydrogen
Material - Flange
Stainless Steel
Material - Insulation
APG-15NA - High Temp Cycloaliphatic Epoxy
Mounting Position
Vertical to Horizontal
Number of Bolt Holes - Bottom Terminal
4
Number of Flange Mounting Holes
12
Plating - Bottom Terminal
Silver
Product Type
Traversée condensatrice SDC
Series
SDC™
Test Tap
No
Top Terminal Plating
Silver
Top Terminal Type
4 1/2-10
Type
SDC - Solid Dielectric Capacitor
Above Flange Length
23.3 in
Below Flange Length
17.25 in
Depth
15.25 in
Diameter - Above Flange Maximum
10.03 in
Diameter - Below Flange Maximum D <gt/> 1"
8.72 in
Diameter - Below Flange Maximum P
8.82 in
Diameter - Conductor Outside Under Insulation
4.5 in
Diameter - Live Part Bottom
8 in
Diameter - Live Part Top
6.5 in
Diameter - Rod / Tube
4.5 in
Dimensions
40.5 in x 15.25 in x 15.25 in
Effective Length - Bottom Terminal
6.00 DIA in
Effective Length - Top Terminal
5.5 in
Flange Mounting Hole Bolt Circle
13.63 in
Flange Mounting Hole Diameter
0.75 in
Flange Outside Diameter
15.25 in
Height
15.25 in
Length
40.5 in
Length - Ground Shield
4.6 in
Length - Insulated Section
30.9 in
Length - Insulation Above Flange
13.2 in
Length - Insulation Below Flange
10.55 in
Length - Live Part Bottom
2.1 in
Length - Live Part Top
7.5 in
Sealing Surface Inside Diameter
8.85 in
Sealing Surface Outside Diameter
12.88 in
Thickness
2.11 in
Thickness - Flange Plate
1.63 in
Top Terminal Min. Thread Length
5.5 in
Weight
251 lb
Width
15.25 in
BIL
82 kV
Current Rating
3400 A
kV Class
13.8 kV
Minimum Creepage
27.2 in
Minimum Creepage - Inside
28 in
Minimum Strike
14.76 in
Minimum Strike - Inside
15.58 in
Withstand Voltage - 60 Hz Dry
34 kV
Industry Standard(s)
SPECIAL
Immersion Type - Above Flange
Air
Immersion Type - Below Flange
Hydrogen
Bottom Terminal Type
CONTACT DISC 6.00 DIA WITH 4X 5/8-11 THREADED HOLES
Mounting Position
Vertical to Horizontal
Number of Bolt Holes - Bottom Terminal
4
Number of Flange Mounting Holes
12